Screen Examples
135
If performing a sun shot, check the
Non-Linear Declination
Correction
checkbox. (Leave it unchecked for star shots.)
Check the
Correct to State Grid
checkbox if you want the
computed azimuth corrected to align with the local state
plane coordinate system.
Note: The
Central Meridian
and
Zone Constant
values for the United
States are provided in Appendix A of the Reference Manual.
7.
Refer to a current ephemeris and fill in the remaining five values.
When the screen is correctly filled in, tap the
Shots
tab.
Note: The GHA0 and Decl0 values are read from the ephemeris for
the current date. The GHA24 and Decl24 values are listed in the
ephemeris for the following day. The semi-diameter is in minutes
and seconds so your value will look something like
0.16084
.
8.
Tap the button to open the Enter Shot Data
screen.
9.
Enter the correct hours to GMT in the
Hrs To GMT
field, aim toward the backsight and tap to
record the horizontal angle to the backsight. (The
true azimuth to this point will be computed at the
end of the routine.)
Note: The hours to GMT will be between -5 and -8 when
in the continental United States.