Set Command Library
ATM,PER: Setting Unique Output Rate for all ATOM Messages
Function This command is used to set the same output rate for all
ATOM messages. This command will overwrite all the output
rates set individually for each message type using
$PASHS,ATM,RNX and $PASHS,ATM,PVT.
Command Format Syntax
$PASHS,ATM,PER,f[*cc]
Parameters
Example
Setting the output rate to 1 second:
$PASHS,ATM,PER,1*5B
Relevant Query
Command
$PASHQ,ATM
See also $PASHS,ATM
ATM,VER: Setting the Version of ATOM Messages
Function This command is used to set the version in which the receiver
will generate ATOM messages on all its ports.
Command Format Syntax
$PASHS,ATM,VER,d[*cc]
Parameter Description Range
f
Output rate.
Setting $PASHS,POP to “20” is a
prior condition to operating at
0.05 s (20 Hz).
0.05 sec or 0.1-0.4 sec if the
[F] option is activated
0.5-0.9 sec
1-999 sec
*cc Optional checksum *00-*FF